Solutions   for   Protecting   andManaging   the   Electrical   Network

NP 900   RANGE

Protection, control, measurement and monitoring IEDs

The optimal management of electrical power systems is based in particular on the reliability, availability and communication skills of protection, measurement and automation devices.
As a significant improvement over its NP800 range, ICE has introduced the NP900 series. This new range includes many advanced features such as IEC 61850 communication protocol as standard, a large graphical display, wider measurement ranges and fully customisable logic functions.
Our user friendly SMARTline (Setting, Measurement, Analysis, Recording, Time-saving) configuration software supports NP900s and includes SMARTsoft for NP800s, Railway and Regulation.
This range is designed for the protection of all types of Generation, Industrial, Railway, Transmission and Distribution networks.

  Device ANSI Description
NP F910 50/51, 50N/51N, 50H/51H/68H, 46R/46L/46, 49L, 87N, 50BF/52BF, 74TC, 79, 68, 86 Current based feeder protection IED
NP F915 50/51, 50N/51N, 67, 67N, 50H/51H/68H, 46R/46L/46, 49L, 87N, 59, 27, 59N, 59P/27P/47, 81O/81U, 81R, 78, 32/37/32R, 50BF/52BF, 21FL, 60, 74TC, 25, 79, 68, 86 Voltage & current based enhanced feeder protection IED
NP M910 50/51, 50N/51N, 50H/51H/68H, 46R/46L/46, 87N, 49M, 48/14, 66, 37, 51M, 50BF/52BF, 74TC, 86 Current based motor protection IED
NP M915 50/51, 50N/51N, 67N, 50H/51H/68H, 46R/46L/46, 87N, 49M, 48/14, 66, 37, 55, 51M, 59, 27, 59P/27P/47, 59N, 81O/81U, 81R, 32/37/32R, 50BF/52BF, 60, 74TC, 86 Voltage & current based enhanced motor protection IED
NP G915 50/51, 50N/51N, 67, 67N, 50H/51H/68H, 46R/46L/46, 87N, 59, 27, 59P/27P/47, 59N, 81O/81U, 81R, 40, 51V, 64S, 32/37/32R, 49M, 21, 24, 78, 50BF/52BF, 60, 74TC, 25 Generator Protection IED
NPT 916 87T, 87N, 49T, 50/51, 50N/51N, 50H/51H/68H, 46R/46L/46, 50BF/52BF, 49L, 74TC, 86 Differential Protection IED
NP TA915 87N, 49T, 50/51, 50N/51N, 50H/51H/68H, 46R/46L/46, 59, 27, 59N, 59P/27P/47, 24, 49L, 50BF/52BF, 60, 74TC, 90 Voltage Regulating and back-up protection IED
NP V911 59, 27, 59N, 59P/27P/47, 78, 81O/81U, 81R, 60, 74TC, 86 Busbar voltage & frequency protection IED
NP S914 Alarming and Indication IED
NP BC915 60, 74TC, 25, 79 Bay Control IED
NP P915 60 Power Monitoring IED
NP E915 Fault location / indication :
50N, 67N, 67NT, 50, 67, 21FL, 27, 59N
Energy Managment IED
CONFIGURATION   SOFTWARE
  Document Description Lang. Ref. Ind.
SMART 9 Software EN -- 1.5.1
SMART 9 Instruction Manual EN A987 C
IEC61850 Configuration Instruction Manual EN A988 A