Solutions for Protecting andManaging the Electrical Network
TTG 7000
Undervoltage and overvoltage relays STATIC RANGE
The TTG relays of series 7000 and 7100 form a complete range of under or overvoltage relays, instantaneous or definite time (independent specified time).
The independent time relays type TTG 7134 and instantaneous relays type TTG 7034 are definite overvoltage relays which have been designed basically for supervision of the zero sequence voltage resulting from an electrical displacement of the neutral point under fault conditions.
The TTG series is supplied in a modular plug-in case type R, which may be mounted either as a separate relay, projecting or flush mounting, or as an element in a standard 19" rack cradle.
PROTECTION FUNCTIONS
- Under voltage [27]
- Over voltage [59]
- Neutral over voltage [59N] (TTG 7034, TTG 7134, TTG 7114)
MAIN FEATURES
- Power supply: 24, 48, 60, 110, 125, 220, 250 Vdc or 100, 110, 127, 220 Vac
- 2 contacts for each output unit
- Hand reset mechanical operation indicator
- Setting by frontal potentiometers
- Instantaneous or time dependent operating characteristics
DOWNLOADS
Device | Doc Type | Lang. | Ref. | Index | |
---|---|---|---|---|---|
TTG 7000 TTG 7100 |
Leaflet | EN / FR | FA846 | A | |
TTG 7114 | Leaflet | EN / FR | -- | -- | |
TTG 7034 TTG 7134 |
Leaflet | EN / FR | FA847 | A | |
TTG 7000 TTG 7100 |
User Manual | EN / FR | M.1713 | G |
UNDER / OVER VOLTAGE - THREE PHASES
TTG 7166 Inst. / Delayed |
Connection/Definition Diagram | EN / FR | 17A2 | C |
UNDER VOLTAGE - SINGLE PHASE
TTG 7012 Instantaneous |
Connection/Definition Diagram | EN / FR | 8727 | K | |
TTG 7013 Instantaneous |
Connection/Definition Diagram | EN / FR | 8116 | H | |
TTG 7112 Time Delayed |
Connection/Definition Diagram | EN / FR | 8728 | H | |
TTG 7113 Time Delayed |
Connection/Definition Diagram | EN / FR | 8115 | F |
UNDER VOLTAGE - TWO PHASES
TTG 7023 Instantaneous |
Connection/Definition Diagram | EN / FR | 8471 | F | |
TTG 7025 Instantaneous |
Connection/Definition Diagram | EN / FR | 8771 | D | |
TTG 7123 Time Delayed |
Connection/Definition Diagram | EN / FR | 8173 | E |
UNDER VOLTAGE - THREE PHASE
TTG 7032 Instantaneous |
Connection/Definition Diagram | EN / FR | 9830 | F | |
TTG 7033 Instantaneous |
Connection/Definition Diagram | EN / FR | 8470 | D | |
TTG 7132 Time Delayed |
Connection/Definition Diagram | EN / FR | 9829 | D | |
TTG 7133 Time Delayed |
Connection/Definition Diagram | EN / FR | 8172 | D |
UNDER VOLTAGE - DIRECT COMPONENT
TTGd 7012 Instantaneous |
Connection/Definition Diagram | EN / FR | 9041 | D | |
TTGd 7123 Time Delayed |
Connection/Definition Diagram | EN / FR | 9042 | D |
OVER VOLTAGE - SINGLE PHASE
TTG 7011 Instantaneous |
Connection/Definition Diagram | EN / FR | 8114 | H | |
TTG 7111 Time Delayed |
Connection/Definition Diagram | EN / FR | 8113 | C |
OVER VOLTAGE - ZERO SEQUENCE
TTG 7114 Time Delayed |
Connection/Definition Diagram | EN / FR | 9383 | F | |
TTG 7034 Instantaneous |
Connection/Definition Diagram | EN / FR | 9793 | B | |
TTG 7134 Time Delayed |
Connection/Definition Diagram | EN / FR | 9749 | D |